Welcome to Iightstrade.com!

Thermal Shock Chamber

MOQ :1 set

Lead Time :20 Days

Seller Support : Trade Authenticity Guaranteed & Accepting

Payment : L/C,T/T,Western Union

Departure Port : ShenZhen

Product details

Supply Ability

  • Supply Ability:10 piecesWarranty(Year):1 Year

Packaging & Delivery

  • Length:46 cmWidth:46 cm
  • Height:46 cm
  • Packaging:1 set

Product Specifications

  • Brand name:ASLI

Product Description

 Thermal Shock Chamber


Thermal Shock Testers/Technical Specifications :

1.TS-42A

2.Studio Size : 46*46*46cm

3.High temperature chamber temperature range : room temperature ~ +150 degree cold room : room temperature ~ -60 degree

4.heating and cooling rate : 1.5 degree per minute on average

5.Temperature fluctuation : less than about 0.5 degree

6.Temperature error: less than about 2 degree

7.temperature conversion time : less than 10S

8.temperature recovery time : less than 5min.              [sales(at)aslitestiing.com]

9.impact of conversion: Conversion cylinder

10.Material Case : SUS # 304 stainless steel liner : SUS # 304 stainless steel

11.Cooling System: two yuan duplex compressor cooling ( air-cooled or water-cooled ) , imported French Taikang compressor , environmentally friendly refrigerant


Thermal Chambers/Control System:

1.with RS-232C communication interface device can be controlled with a computer online / editing / recording , and two group dynamic contacts (TimeSignalRelay), easy to use.

2.perform thermal shock conditions , choose 2Zone or 3Zone function.

3.have fully automated , high-precision system loop , either mechanical action, completely locked processed by the PLC.

4.The mechanical defects , with automatic machine loops and warning signals . When the input power was found unstable , with emergency stop devices.

5.Uses: mainly used in electronic components, high temperature material impact test.


Cold Thermal Shock Tester/Features:

1.Europe's most advanced new proof handle , perfect design , the appearance of the texture of a high standard .

2.using a large man-machine dialogue LED machine interface touch controller , simple operation, easy to learn , stable and reliable.

3.Impact method using style switching mode , the cold and hot temperatures into the test area to achieve thermal shock testing purposes.

4.Impact time of 0.1 to 999.9 hours , cycle times can be set from 1 to 9999 .

5.to set the number of automatic defrost cycles and (manual ) defrost .


Application of standards and meet the standards

1.GB/T2423.1-1989 cryogenic test methods ;

2.GB/T2423.2-1989 high temperature test methods ;

3.GB/T2423.22-1989 temperature test ;

4.GJB150.5-86 Thermal Shock Test ;

 